Structured information on the device
Please fill the following questionnaire with specific data of the device you designed in WP3 and fabricated and validated in WP4. Deviations from the questionnaire in WP2 are possible.
User and evironment
Who is the intended user? | Self-user/patient |
---|---|
Is training required in addition to the expected skill level of the intended user? | No |
Is any maintenance or calibration required by the user at the time of use? | No |
Where will the technology be used? | indoors, at home, primary level (health post, health center), secondary level (general hospital) |
Health technology specifications
Dimensions (mm3) | 90 mm x 180 mm x 10 mm |
---|---|
Weight (kg) | 0.25 kg |
Does it require the use of consumables? For example, disposable batteries, disposable electrodes, etc. | No |
Estimated life time | 1 Years |
Estimated shelf life | 6 Months |
Can it have a telemedicine or eHealth application? | Yes |
Does it use any kind of software? | Yes |
If yes, please describe the software, whether it is open source or proprietary, its use and/or license fee, etc. (10-70 words). | This software will be sold to clinics, which have to pay an application fee and an extra percentage depending on the number of users who use the app. In addition, it will be free to download, with advertising and limited functionality.This software will be sold to clinics, which have to pay an application fee and an extra percentage depending on the number of users who use the app. In addition, it will be free to download, with advertising and limited functionality.This software will be sold to clinics, which have to pay an application fee and an extra percentage depending on the number of users who use the app. In addition, it will be free to download, with advertising and limited functionality.This software will be sold to clinics, which have to pay an application fee and an extra percentage depending on the number of users who use the app. In addition, it will be free to download, with advertising and limited functionality. |
If yes, can the software be customized for local use? Please explain (10-70 words). Include languages available. | The first version of this application does not have a high customisation possibility, it only allows the choice of the patient's gender. |
Is it portable? | Portable |
Type of use | Long term use |
Does the technology require maintenance? |
No |
Energy requirements |
Batteries |
Facility requirements |
Access to the Internet Access to a cellular phone network Connection to a laptop/computer Additional sound / light control facilities |