User and evironment

Who is the intended user? Self-user/patient
Is training required in addition to the expected skill level of the intended user? No
Is any maintenance or calibration required by the user at the time of use? No
Where will the technology be used? indoors, at home, primary level (health post, health center), secondary level (general hospital)

Health technology specifications

Dimensions (mm3) 90 mm x 180 mm x 10 mm
Weight (kg) 0.25 kg
Does it require the use of consumables? For example, disposable batteries, disposable electrodes, etc. No
Estimated life time 1 Years
Estimated shelf life 6 Months
Can it have a telemedicine or eHealth application? Yes
Does it use any kind of software? Yes
If yes, please describe the software, whether it is open source or proprietary, its use and/or license fee, etc. (10-70 words). This software will be sold to clinics, which have to pay an application fee and an extra percentage depending on the number of users who use the app. In addition, it will be free to download, with advertising and limited functionality.This software will be sold to clinics, which have to pay an application fee and an extra percentage depending on the number of users who use the app. In addition, it will be free to download, with advertising and limited functionality.This software will be sold to clinics, which have to pay an application fee and an extra percentage depending on the number of users who use the app. In addition, it will be free to download, with advertising and limited functionality.This software will be sold to clinics, which have to pay an application fee and an extra percentage depending on the number of users who use the app. In addition, it will be free to download, with advertising and limited functionality.
If yes, can the software be customized for local use? Please explain (10-70 words). Include languages available. The first version of this application does not have a high customisation possibility, it only allows the choice of the patient's gender.
Is it portable? Portable
Type of use Long term use
Does the technology require maintenance?

No

Energy requirements

Batteries

Facility requirements

Access to the Internet

Access to a cellular phone network

Connection to a laptop/computer

Additional sound / light control facilities